Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment

Product Details
Customization: Available
Certification: ISO9001, CE
Salt Rejection Rate: 99.5%
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
33
Year of Establishment
2015-12-29
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
  • Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
Find Similar Products

Basic Info.

Model NO.
JFRO-2T
Application
Industry
Capacity
2t
RO Frame
SUS304
Warranty
1year
Host Size
800X600X1600mm (Can Be Customized)
Power
2.2kw
Producing Capacity
2t/H
Membrane Size
8040
Membrane Elements
Dow/Hydranautics/Troy/Vontron(Optional)
Recovery Rate
50%
Desalination Rate
99.5%
Tank Material
Ss/FRP(Optional)
Control Valve
Automatic
Control Valve Brand
Fleck/Runxin
Raw Water Pump
Cnp/Nyp/ (Optional)
Operating Pressure
0.8-1.2MPa
Designed Water Inlet
4t/H
Transport Package
Wooden Packing
Specification
3.5m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
500pieces/Year

Packaging & Delivery

Package Size
150.00cm * 95.00cm * 220.00cm
Package Gross Weight
700.000kg

Product Description

Reverse Osmosis water filter system desalination portability filtration equipment

 

Reverse osmosis water system is the raw water through the precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, Remove trace ions, organic matter and other impurities in reverse osmosis pure water in one step.

 

The principle of reverse osmosis water treatment equipment is mainly reverse osmosis technology. Sufficient pressure is used to separate the solvent in the solution (usually water) through a reverse osmosis membrane (a semi-permeable membrane) in the opposite direction to the osmosis direction, which can be used to separate, purify and concentrate the solution by reverse osmosis greater than the osmotic pressure.


Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment

Definition of RO Water Treatment System

 

The reverse osmosis water treatment system uses municipal water as raw water, passes through a pre-filter (water softener is optional), and reverse osmosis membrane treats the water.

Reverse osmosis water system is the raw water through the precision filter, granular activated carbon filter, activated carbon filter, compression, and then through the pressure of the pump, the use of reverse osmosis membrane pore size 1/10000 microns to make relatively high concentrations of water into the low concentration of water, and industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed in the water of a large number of sufficient isolation, It can remove more than 98% of soluble salts and more than 99% of colloid, microorganisms, particles and organic matter in water.

 

Technical Parameters of RO Water Treatment System
 

Model JFRO-2000L
Host Size 2700x600x1600mm (can be customized)
Power 3KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 67%
Designed Water Inlet 3000L/h
Outlet Flow 2000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 8
Raw Water Pump CNP/NYP/(Optional)
High Pressure Pump CNP/NYP (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP
Number of Membrane housing 4
Pipe Material

U-PVC/ Stainless steel (Optional)

 

Introduction of RO Water Treatment System Consumables

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

The pretreatment of reverse osmosis water treatment system can ensure the stable operation and service life of reverse osmosis device, and has the following functions:

 

(1) To prevent scaling on the film surface (including CaCo3, CaSO4, SrSO4, CaF2, SiO2, iron and aluminum oxide, etc.);

(2) to prevent colloidal substances and suspended solid particles fouling;

(3) to prevent pollution and blockage of organic matter;

(4) to prevent microbial fouling;

(5) to prevent oxidative damage to the film by oxidizing substances;

(6) Keep the water yield of reverse osmosis device stable.

 

Reverse osmosis water treatment pretreatment system: iron and manganese filter, multi-media filter, activated carbon filter, sodium ion exchanger, precision filter, ultrafiltration.

Process flow of RO water treatment system:
Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment

Composition of RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment

Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment
Reverse Osmosis Water Filter System Desalination Portability Filtration EquipmentReverse Osmosis Water Filter System Desalination Portability Filtration Equipment
Reverse Osmosis Water Filter System Desalination Portability Filtration Equipment

Reverse Osmosis Water Filter System Desalination Portability Filtration EquipmentReverse Osmosis Water Filter System Desalination Portability Filtration Equipment

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier