Customization: | Available |
---|---|
Certification: | ISO9001, CE |
Salt Rejection Rate: | 99.5% |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Drinking water RO system membrane:
It is a semi-permeable membrane artificially synthesized by a special process in order to realize the reverse osmosis phenomenon of the aqueous solution. The pore size of the reverse osmosis membrane is 0.0001µm, and only the solvent in the aqueous solution, water, can pass through, while its solute cannot pass through the reverse osmosis membrane. The diameter of the virus is 0.02-0.4µm, and the diameter of the bacteria is 0.4-1.0µm. Therefore, the water passing through the reverse osmosis membrane is truly pure water.
What size unit of RO Water Treatment System do I need to purchase?
For different types of water, the limits of osmotic flux and elemental recovery in ro water treatment system are based on the correlation between SDI value and membrane contamination and the correlation between mineral content and elemental recovery respectively. For example, systems designed to have high permeability flux rates may experience higher scaling rates and more frequent chemical cleaning. The design of seawater systems is further limited by osmotic pressure and durability of membrane elements due to high salinity (> 36,000 PPM TDS).
Product Introduction of RO Water Treatment System
Design Features:
1. Achieve deep filtration of water by increasing the pressure on water. In addition to general filters, reverse osmosis pure water equipment also has fine filters, granular activated carbon filters and compressed activated carbon filters. The fine filter has a finer filtering function than the general filter, and can better filter impurities in the water. As we know, activated carbon has a good adsorption and filtration function for odors and impurities. The reverse osmosis pure water equipment uses double activated carbon filters to realize the deep filtration of raw water and improve the filtration efficiency of the equipment. At the same time, it is also an innovation to enhance the filtration capacity by increasing the pressure of the water.
2. The core of reverse osmosis pure water equipment is the application of reverse osmosis membrane. The reverse osmosis membrane is a filter membrane with extremely small pore size. Using this membrane can realize ultra-fine filtration of raw water, and can divide water into high concentration and low concentration at the same time. Water with a higher concentration can be recycled and reused, and water with a lower concentration is pure water that can be used by humans.
Technical Parameters of RO Water Treatment System
Model | JFRO-6000L |
Host Size | 3000x800x1600mm (can be customized) |
Power | 5.5KW |
Power Supply | 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure | 0.8-1.2MPa |
Recovery Rate | 60% |
Designed Water Inlet | 10000L/h |
Outlet Flow | 6000L/h |
Desalination Rate | ≥99.5% |
RO Frame | SUS304 |
Membrane Size | 8040 |
Membrane Elements | DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes | 6 |
Raw Water Pump | CNP/NYP/ (Optional) |
High Pressure Pump | CNP/NYP/ (Optional) |
Tank Material | SS/FRP(Optional) |
Control Valve | Manual/Automatic |
Control Valve Brand | FLECK/RUNXIN |
Membrane Housing | FRP |
Number of Membrane housing | 3 |
Pipe Material | U-PVC/ Stainless steel (Optional) |
Introduction of RO Water Treatment System Consumables
1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;
2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)
Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)
4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;
5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;
6. High pressure pump: provide high pressure to reverse osmosis membrane;
7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);
8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).
The pretreatment of reverse osmosis water treatment system can ensure the stable operation and service life of reverse osmosis device, and has the following functions:
(1) To prevent scaling on the film surface (including CaCo3, CaSO4, SrSO4, CaF2, SiO2, iron and aluminum oxide, etc.);
(2) to prevent colloidal substances and suspended solid particles fouling;
(3) to prevent pollution and blockage of organic matter;
(4) to prevent microbial fouling;
(5) to prevent oxidative damage to the film by oxidizing substances;
(6) Keep the water yield of reverse osmosis device stable.
Reverse osmosis water treatment pretreatment system: iron and manganese filter, multi-media filter, activated carbon filter, sodium ion exchanger, precision filter, ultrafiltration.
Process flow of RO water treatment system:
Composition of RO Water Treatment System
Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.
1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.
2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.
3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.
4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.
5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.