• 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
  • 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
  • 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
  • 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
  • 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
  • 2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

Certification: ISO9001, CE
Salt Rejection Rate: 99.5%
Application: Industry
Capacity: 2t
RO Frame: SUS304
Warranty: 1year
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
JFRO-2T
Host Size
800X600X1600mm (Can Be Customized)
Power
2.2kw
Producing Capacity
2t/H
Membrane Size
8040
Membrane Elements
Dow/Hydranautics/Troy/Vontron(Optional)
Recovery Rate
50%
Desalination Rate
99.5%
Tank Material
Ss/FRP(Optional)
Control Valve
Automatic
Control Valve Brand
Fleck/Runxin
Raw Water Pump
Cnp/Nyp (Optional)
Operating Pressure
0.8-1.2MPa
Designed Water Inlet
4t/H
Transport Package
Wooden Packing
Specification
3.5m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
500pieces/Year

Product Description

2000LPH ro water treatment plant water desalination machines reverse osmosis

 

What is Reverse Osmosis Water Treatment System?

 

Reverse osmosis water treatment system is usually composed of raw water pretreatment system, reverse osmosis purification system and ultra-purification post-treatment system. Membrane separation technology is applied to remove charged ions, inorganic matter, colloidal particles, bacteria and organic matter from water. Reverse osmosis membrane system is the most economical and efficient purification method to remove more than 98% ions, organic matter and 100% microorganisms (theoretically) in raw water at one time.

 

Working Principle of Reverse Osmosis Water Treatment System:

 

When a pressure greater than osmotic pressure is applied on the saltwater side of the membrane, the flow of water is reversed and the water in the saltwater flows into the fresh side, a phenomenon called reverse osmosis.


Application fields of RO Water Treatment System


1. Water for food and beverage industries
Beverages, dairy, brewing, preparation water, low-level blending water, pure draft beer filtration
2. Bottled and bottled drinking water
Drinking pure water, natural water, mineral water, mineralized water
3. Family and group water purification equipment
High-quality water supply network systems and swimming pool water purification equipment for buildings, communities, hotels, airports, real estate properties


2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

What size unit of RO Water Treatment System do I need to purchase?

 

For different types of water, the limits of osmotic flux and elemental recovery in ro water treatment system are based on the correlation between SDI value and membrane contamination and the correlation between mineral content and elemental recovery respectively. For example, systems designed to have high permeability flux rates may experience higher scaling rates and more frequent chemical cleaning. The design of seawater systems is further limited by osmotic pressure and durability of membrane elements due to high salinity (> 36,000 PPM TDS).

 

Characteristics of RO Water Treatment System

 

Compared with other water treatment methods, it has the advantages of no phase change, normal temperature operation, simple equipment, high efficiency, less occupation, convenient operation, less energy consumption, wide range of adaptation, high degree of automation and good effluent quality. Reverse osmosis desalination rate and purity of produced water are higher than electrodialysis, for high fluoride and low salinity brackish water desalination by reverse osmosis, effluent water quality can reach our daily drinking purified water health standards. And reverse osmosis desalination brackish water energy consumption - - electricity consumption, water consumption are lower than electrodialysis, and reverse osmosis equipment compact structure, small footprint, stable and reliable operation effect, in line with the "clean production" requirements, reverse osmosis is more reasonable than other methods, effective desalination brackish water method.

 

Ro water treatment system method is used to desalinate brackish water with different salt content. The desalting rate of the system is above 96 %, and the quality of desalted water reaches the standard of drinking water. The brackish water desalination device of reverse osmosis system has strong adaptability. It can realize continuous treatment of brackish water with different salt content by adjusting operation parameters according to the quality of raw water. The device is highly integrated and is expected to become a complete set of finalized equipment.

 

Technical Parameters of RO Water Treatment System
 

Model JFRO-2000L
Host Size 2700x600x1600mm (can be customized)
Power 3KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 67%
Designed Water Inlet 3000L/h
Outlet Flow 2000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 8
Raw Water Pump CNP/NYP (Optional)
High Pressure Pump CNP/NYP (Optional)
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP
Number of Membrane housing 4
Pipe Material

U-PVC/ Stainless steel (Optional)

 

Introduction of RO Water Treatment System Consumables

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

The pretreatment of reverse osmosis water treatment system can ensure the stable operation and service life of reverse osmosis device, and has the following functions:

 

(1) To prevent scaling on the film surface (including CaCo3, CaSO4, SrSO4, CaF2, SiO2, iron and aluminum oxide, etc.);

(2) to prevent colloidal substances and suspended solid particles fouling;

(3) to prevent pollution and blockage of organic matter;

(4) to prevent microbial fouling;

(5) to prevent oxidative damage to the film by oxidizing substances;

(6) Keep the water yield of reverse osmosis device stable.

 

Reverse osmosis water treatment pretreatment system: iron and manganese filter, multi-media filter, activated carbon filter, sodium ion exchanger, precision filter, ultrafiltration.

Process flow of RO water treatment system:
2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

Composition of RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone
2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone2t/H Reverse Osmosis System Drinking Water System with UV Sterilizer Ozone

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now