RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System

Product Details
Customization: Available
Type: Reverse Osmosis
Usage: Environmental Protection, Chemical Industry, Seawater Desalination System
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
33
Year of Establishment
2015-12-29
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
  • RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
Find Similar Products

Basic Info.

Model NO.
JFRO-1000LPH
Motive Force
Electric power
Style
Tube
Performance
Efficient Filtration
Certification
CE, ISO9001, CE
Salt Rejection Rate
99.5%
Application
Industry
RO Frame
SUS304/Carbon Steel (Optional)
Warranty
12 Months Warranty and Lifetime Service
Power
110kw
Function
Water Purification
Operating Pressure
1.2-1.5MPa
Membrane Size
8040
NBR of Membrane
108
NBR of Membrane Housing
18
Desalination Rate
99.5%
Recovery Rate
50%
Product Name
RO Water Treatment System
Voltage
110V/220V/380V Can Be Customized
Materials
FRP, Stainless Steel, UPVC
Transport Package
Wooden Packing
Specification
6m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
2000pieces/Year

Product Description

Water treatment system 1000LPH Drinking Water RO plant Reverse Osmosis
 

How does temperature affect water production?


The higher the temperature, the higher the water production, and vice versa, when operating at a higher temperature, the operating pressure should be lowered to keep the water production unchanged, and vice versa.

RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System


Flow chart of Ro Water Treatment System

 

Source water tank → source water booster pump → multi-media filter → activated carbon filter → cation resin softener → precision filter → primary RO reverse osmosis pure water system → secondary RO reverse osmosis pure water system → water gas mixer →Ozone sterilizer→Stainless steel pure water tank→Automatic filling line
 

RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System

Operating environment of drinking water RO system:
 
1. Indoor ambient temperature: 5~35ºC.
2. Temperature: 80% larger.
3, to achieve no pollution, no vibration.
4. The room should be cool, dry, ventilated, and avoid direct sunlight.
5. The installation ground of the equipment is guaranteed to be flat, drainable and water will not leak.
6. The equipment installation room meets the space area required for the equipment to work


Technical details of RO Water Treatment System
 

Model

JFRO-1000L

Host Size

1000x600x1600mm (can be customized)

Power

2.2KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

2000L/h

Outlet Flow

1000L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

4

Raw Water Pump

CNP/NYP/ (Optional)

High Pressure Pump

CNP/NYP/ (Optional)

Tank Material

SS/FRP(Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP

Pipe Material

U-PVC/ Stainless steel (Optional)

 

Reverse osmosis water treatment system has poor filtration effect:

 

There are many reasons for the poor filtering effect, such as: the selection of filter material variety, filling amount is unreasonable, filter cycle backwash scrubbing time control is unreasonable, will lead to high SDI.

 

Low removal rate of organic matter

1. Improve the pretreatment process and improve the measures of COD reduction in the system

2. Try to replace other non-oxidizing fungicides for COD removal.

3. Replace or regenerate when the COD adsorption of the filter material of activated carbon filter is full.
 

Advantages of RO reverse osmosis membrane:

 

1. Cross-flow operation process, strong anti-pollution ability, good regeneration performance and long service life.

2. The separation precision is high, and the permeated liquid is clear and transparent, which greatly reduces the load of the subsequent refining process.

3. Achieve high multiple concentration of fermentation broth and improve product yield.

4. While improving the product yield, the bacteria in the fermentation broth can be recovered, bringing more profit points and environmental protection benefits to the enterprise.

5. There is no need for filter aids in the treatment process, and there is no retention of active ingredients in the fermentation broth.

6. Realize clean production, reduce the amount of acid, alkali and water washing, and greatly improve the biodegradability of wastewater.

7. There is no phase change during system operation, low energy consumption and lower production cost


RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination SystemRO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System
RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System

RO System 1000lph Drinking Water RO Plant Reverse Osmosis Water Desalination System


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier