Customized Water Desalination RO System to Drinking Water

Product Details
Customization: Available
Certification: ISO9001, CE
Salt Rejection Rate: 99.5%
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
33
Year of Establishment
2015-12-29
  • Customized Water Desalination RO System to Drinking Water
  • Customized Water Desalination RO System to Drinking Water
  • Customized Water Desalination RO System to Drinking Water
  • Customized Water Desalination RO System to Drinking Water
  • Customized Water Desalination RO System to Drinking Water
  • Customized Water Desalination RO System to Drinking Water
Find Similar Products

Basic Info.

Model NO.
JFRO-2000L
Capacity
2000L/H
Raw Water Pump
Cnp
Membrane Elements
Vontron
Power Supply
220V /380V/460V - 50Hz/60Hz, 220V 50Hz
Recovery Rate
67%
Designed Water Inlet
3000L/H
Outlet Flow
2000L/H
Membrane Housing
Ss
RO Frame
SUS304
Tank Material
FRP
Control Valve
Automatic
Control Valve Brand
Runxin
Pipe Material
U-PVC
Transport Package
Wooden Case
Specification
13CBM
Trademark
JUFU
Origin
China
HS Code
8421219990

Product Description

Customized Water Desalination RO System To Drinking Water
 
Product Introduction of RO Water Treatment System

RO equipment is reverse osmosis equipment. Reverse osmosis equipment passes raw water through fine filters, granular activated carbon filters, compressed activated carbon filters, etc., and then pressurizes through pumps. 1/6000, 1/300 of the virus) reverse osmosis membrane (RO membrane), so that the higher concentration of water into low concentration water, while industrial pollutants, heavy metals, bacteria, viruses and other impurities mixed into the water are all isolated , so as to achieve drinking.

 

The Basic Working Principle of RO Water Treatment System
After a special high-pressure pump, when the raw water is added to a pressure of 6-20 kg, the raw water permeates through the reverse osmosis membrane with a pore size of only 0.0001 microns under the action of pressure. Chemical ions, bacteria, fungi, and virions cannot pass through, and are discharged with wastewater. Only water molecules and solvents with a volume of less than 0.0001 microns are allowed to pass through.


Product Accessories Display of 2000LPH RO Water Treatment System
Customized Water Desalination RO System to Drinking Water
Technical Specifications of 2000LPH RO Water Treatment System

 

2000LPH Reverse Osmosis System
Model JFRO-2000L
Host Size 2700x600x1600mm (can be customized)
Power 3KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 67%
Designed Water Inlet 3000L/h
Outlet Flow 2000L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements Vontron (Optional)
Number of Membranes 8
Raw Water Pump CNP
High Pressure Pump CNP
Tank Material SS/FRP(Optional)
Control Valve Manual/Automatic
Control Valve Brand RUNXIN
Membrane Housing SS/FRP
Number of Membrane housing 4
Pipe Material U-PVC/ Stainless steel (Optional)


Advantages of RO water treatment system:
Reverse osmosis equipment belongs to physical desalting method, which has many advantages.
1) Non-phase-change physical method was used to desalinate and purify the saline water under norma temperature.
2) Desalting rate of single membrane element is 99.3% and can remove colloid, organics, bacteria, virus and all kinds of heavy metals in water at the same time.
3) With water pressure as the driving force, energy consumption is the lowest among many treatment methods.
4) No need for large amount of chemical treatment, no elimination of chemical waste liquid, no environmental pollution, and the recovery rate is over 70%.
5) High automation program, automatic stop in case of ailure, with automatic protection function.
6) The system is simple, easy to operate, and the water quality is stable.
7) Equipment covers small area, compact structure, reliable operation and high water quality.
 
Process flow of RO Water Treatment System
Raw water → Raw water tank → Raw water pump → Multi-media filter (quartz sand filter) → Activated carbon filter → Soft water processor → Precision filter → High pressure pump → Primary reverse osmosis (RO) device → Purified water tank → High pressure pump → Two Stage reverse osmosis → ultraviolet sterilization device → water point.
 
Customized Water Desalination RO System to Drinking Water

Picture of Reverse Osmosis Water Treatment System

Customized Water Desalination RO System to Drinking Water
Packaging and Logistics

Customized Water Desalination RO System to Drinking Water
Company Exhibition

Customized Water Desalination RO System to Drinking Water


 JUFU's Five Guarantees
Customized Water Desalination RO System to Drinking Water

 JUFU's Business Partner
Customized Water Desalination RO System to Drinking Water

 FAQ:
 
1. What is the design water yield of ro membrane element? (except anti-pollution membrane and seawater desalination membrane)
 
Model 4040 is designed by 0.25m3/h
 
Model 8040 is designed by 1-1.2m3/h
 
2. What is the material of mechanical filter?
 
Carbon steel, stainless steel, fiberglass
 
3.What are the multi-way control valves?
 
Manual control valve, automatic control valve
 
Multi - way control valve is divided into: filter valve and softening valve
 
Automatic control valve is divided into: time type and flow type.
 
Multi-way control valve brands are: FLECK, AUTOTROL, Runxin, clean source, etc.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier