• Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
  • Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
  • Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
  • Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
  • Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
  • Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

Certification: ISO9001, CE
Salt Rejection Rate: 99.5%
Application: Industry
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant pictures & photos
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
US $1,000-3,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
JFRO-500L
Capacity
500liter
RO Frame
SUS304
Warranty
1year
Host Size
800X600X1600mm (Can Be Customized)
Power
2.2kw
Producing Capacity
500L/H
Membrane Size
4040
Membrane Elements
Dow/Hydranautics/Troy/Vontron(Optional)
Recovery Rate
50%
Desalination Rate
99.5%
Tank Material
Ss/FRP(Optional)
Control Valve
Automatic
Control Valve Brand
Fleck/Runxin
Raw Water Pump
Cnp/Nyp/ (Optional)
Operating Pressure
0.8-1.2MPa
Designed Water Inlet
1000L/H
Transport Package
Wooden Packing
Specification
3.5m3
Trademark
Jufu
Origin
China
HS Code
8421219990
Production Capacity
1000pieces/Year

Packaging & Delivery

Package Size
150.00cm * 95.00cm * 220.00cm
Package Gross Weight
700.000kg

Product Description

Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
 

Characteristics of RO Water Treatment System

 

Reverse osmosis water treatment system can remove more than 90 % of soluble salts and 99 % of colloidal microorganisms and organic matter from water. Reverse osmosis water treatment system is suitable not only for seawater desalination, but also for brackish water desalination. Of the existing desalination methods, reverse osmosis desalination is the most economical, it has even exceeded the electrodialysis desalination. As the driving force of reverse osmosis process is pressure, there is no phase change in the process, and the membrane only plays the role of "screening", so the energy consumption of reverse osmosis separation process is low. In existing seawater and brackish water desalination, reverse osmosis is the most energy saving. Reverse osmosis membrane separation is characterized by its "broad spectrum" separation, that is, it can not only remove all kinds of ions in the water, but also can remove particles larger than the ions, such as most of the organic matter, colloid, virus, bacteria, suspended matter, so reverse osmosis separation method is also known as broad spectrum separation.



Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

What size unit of RO Water Treatment System do I need to purchase?

 

For different types of water, the limits of osmotic flux and elemental recovery in ro water treatment system are based on the correlation between SDI value and membrane contamination and the correlation between mineral content and elemental recovery respectively. For example, systems designed to have high permeability flux rates may experience higher scaling rates and more frequent chemical cleaning. The design of seawater systems is further limited by osmotic pressure and durability of membrane elements due to high salinity (> 36,000 PPM TDS).

 

Characteristics of RO Water Treatment System

 

Compared with other water treatment methods, it has the advantages of no phase change, normal temperature operation, simple equipment, high efficiency, less occupation, convenient operation, less energy consumption, wide range of adaptation, high degree of automation and good effluent quality. Reverse osmosis desalination rate and purity of produced water are higher than electrodialysis, for high fluoride and low salinity brackish water desalination by reverse osmosis, effluent water quality can reach our daily drinking purified water health standards. And reverse osmosis desalination brackish water energy consumption - - electricity consumption, water consumption are lower than electrodialysis, and reverse osmosis equipment compact structure, small footprint, stable and reliable operation effect, in line with the "clean production" requirements, reverse osmosis is more reasonable than other methods, effective desalination brackish water method.

 

Ro water treatment system method is used to desalinate brackish water with different salt content. The desalting rate of the system is above 96 %, and the quality of desalted water reaches the standard of drinking water. The brackish water desalination device of reverse osmosis system has strong adaptability. It can realize continuous treatment of brackish water with different salt content by adjusting operation parameters according to the quality of raw water. The device is highly integrated and is expected to become a complete set of finalized equipment.

 

Technical Parameters of RO Water Treatment System
 

Model

JFRO-500L

Host Size

800x600x1600mm (can be customized)

Power

1.5KW

Power Supply

220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized

Operating Pressure

0.8-1.2MPa

Recovery Rate

50%

Designed Water Inlet

1000L/h

Outlet Flow

500L/h

Desalination Rate

≥99.5%

RO Frame

SUS304

Membrane Size

4040

Membrane Elements

DOW /Hydranautics/Troy/ Vontron (Optional)

Number of Membranes

2

Raw Water Pump

CNP/NYP/ (Optional)

Raw Water Pump

CNP/NYP/(Optional)

Tank Material

SS/FRP (Optional)

Control Valve

Manual/Automatic

Control Valve Brand

FLECK/RUNXIN

Membrane Housing

SS/FRP (Optional)

Pipe Material

U-PVC, Stainless steel (Optional)

 

Introduction of RO Water Treatment System Consumables

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

RO Water Treatment System consumables:

 

1. Original water pump: to provide pressure to quartz sand filter/activated carbon filter/water softener;

2. Quartz sand filter: glass fiber as the shell, filled with quartz sand, can filter large particle impurities, suspended matter, colloid, etc.. It is important to remove sediment; (Optional shell and stainless steel, carbon steel)

Activated carbon filter: glass fiber as shell, filled with activated carbon, remove color, odor, residual chlorine and organic matter; (Optional shell and stainless steel, carbon steel)

4. Safety filter: prevent large particles, bacteria and viruses from entering RO film, accuracy is 5μm;

5. Reverse osmosis system: can remove particles, colloid, organic impurities, heavy metal ions, bacteria, virus, heat source, etc. Hazardous substances and 99% dissolved salt;

6. High pressure pump: provide high pressure to reverse osmosis membrane;

7. Polypropylene filter cartridge: interception of large particles, bacteria and viruses with accuracy greater than 5μm. (Optional);

8. Folding filter cartridge: intercept large particles, bacteria and viruses with accuracy > 0.22μm. (optional).

 

There are several consumables that you need to replace regularly.

A. Quartz sand: replaced approximately every 36 months. 50kg/bag

B. Activated carbon: Replace it approximately every 15 months. 25kg/bag

C. Resin: Replaced approximately every 15 months. 25 l/bag

D. Polypropylene cartridge: approximately every 3-6 months to replace


Process flow of RO water treatment system:
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

Composition of RO Water Treatment System

 

Reverse osmosis purified water treatment system generally includes pretreatment system, reverse osmosis device, post-treatment system, cleaning system and electrical control system.

 

1, the pretreatment system generally includes the original water pump, dosing device, quartz sand filter, activated carbon filter, precision filter, etc. Its main function is to reduce the pollution index of raw water and other impurities such as residual chlorine to meet the requirements of reverse osmosis inlet water.

2. Reverse osmosis device mainly consists of multistage high pressure pump, reverse osmosis membrane element, membrane shell (pressure vessel), bracket and so on. Its main function is to remove impurities in water, so that the water meets the requirements of use.

3. Post-treatment system is an additional configuration in the case that reverse osmosis cannot meet the requirements of outlet water. Mainly including negative bed, positive bed, mixed bed, sterilization, ultrafiltration and other one or more of the equipment.

4, cleaning system is mainly composed of cleaning water tank, cleaning water pump, precision filter. When the reverse osmosis system is polluted and the effluent index cannot meet the requirements, it is necessary to clean the reverse osmosis system to restore its efficacy.

5. Electrical control system is used to control the normal operation of the whole reverse osmosis system. Including instrument panel, control panel, all kinds of electrical protection, electrical control cabinet, etc.
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment PlantReverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment PlantReverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant

 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant pictures & photos
Reverse Osmosis Water Filter System 500lph Fully Auto Water Treatment Plant
US $1,000-3,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
33
Year of Establishment
2015-12-29