1000LPH RO Reverse Osmosis Drinking Water Purification Plant Water Filter System Water Treatment System Water Filter Pure Water Making Machine
Reverse Osmosis is a technology that is widely used to remove a large majority of contaminants from water by pushing the water under pressure through a semi-permable membrane.
The RO reverse osmosis membrane has strong compactness and high removal rate of viruses and bacteria, but it should be noted that in many cases, the growth of microorganisms may still occur on the water production side of the membrane, which mainly depends on the way of assembly, monitoring and maintenance, that is, the system The ability to remove microorganisms depends critically on the proper design, operation and management of the system rather than the properties of the membrane elements themselves.
Important indicators of reverse osmosis system
In the selection of reverse osmosis equipment, there is an extremely important indicator - the desalination rate, which determines the quality of the produced water. Rejection rate refers to the percentage of soluble impurities removed from the influent water of the system through the reverse osmosis membrane. This number can be seen from the RO membrane's ability to filter impurities in the water. In addition, there are organic substances, microorganisms, solid particles and residual chlorine in the water, which have a fouling effect on the reverse osmosis membrane, and need to be pretreated to avoid the reduction of the desalination rate caused by the blockage and damage of the membrane surface.
Specifications of JFRO-1000LPH Reverse Osmosis System
1m³/h Reverse Osmosis System |
Model |
JFRO-1000L |
Host Size |
1000x600x1600mm (can be customized) |
Power |
2.2KW |
Power Supply |
220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized |
Operating Pressure |
0.8-1.2MPa |
Recovery Rate |
50% |
Designed Water Inlet |
2000L/h |
Outlet Flow |
1000L/h |
Desalination Rate |
≥99.5% |
RO Frame |
SUS304 |
Membrane Size |
4040 |
Membrane Elements |
DOW /Hydranautics/Troy/ Vontron (Optional) |
Number of Membranes |
4 |
Raw Water Pump |
CNP/NYP/(Optional) |
High Pressure Pump |
CNP/NYP/(Optional) |
Tank Material |
SS/FRP(Optional) |
Control Valve |
Manual/Automatic |
Control Valve Brand |
RUNXIN |
Membrane Housing |
SS/FRP |
Pipe Material |
U-PVC/ Stainless steel (Optional) |
RO Feed Water Requirement |
Silt Density Index (SDI) |
15<5 |
Turbidity |
<1.0 NTU |
Organic matter content |
<1.5 |
Free residual chlorine |
polyamide composite membrane <0.1mg/L |
Operating temperature |
4ºC~45ºC for composite membrane |
Residual chlorine content |
<0.1mg/L |
Iron content |
Fe<0.05 when dissolved oxygen >5mg/L |
Silicon dioxide content |
SiO2<100 |